AT 40T volume control is made of a control circuit having a selector and a separated transformer.
It can be used in 100 V line systems to adjust the volume level of a loudspeaker group having a total power not exceeding 40 W.
All connected loudspeakers shall have 100 V line matching transformers.
It includes a 24 V dc override relay to either bypass the 6 position (5 + off) selector or insert a second 100 V line (not affected by the volume control) for paging.
It can operate with 3 wire lines as well (in order to make emergency announcements without using the internal 24 V dc relay).
AT 40T can be installed on whichever supporting frame for home / office electrical systems by drilling a hole in a blank key and fixing the control circuit.
3 knobs are included in 3 different colours: white, silver, anthracite. If there is enough room, the transformer can be put inside the wall / flushmounted box (where the control circuit is).