EN54 VOICE ALARM SYSTEMS

Reset Filters
Filter By  
Reset Filters
Show Results  

Compare

  • Add a product
  • Add a product
  • Add a product
SELECT AT LEAST TWO PRODUCTS TO COMPARE DETAILS
refine your search
SYSTEM
DXT 3000 (4)
DXT 7000 (3)
DXT 9000 (4)
SYSTEM


Total Results: 8

Display

48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
Compare
PS 6648 is a power supply unit suitable to get continuity power for EN 54-16 systems units like DXT 9000 and DXT 7000, and relevant complementary devices in case of mains power supply interruptions. It includes recharging and monitoring functions for the lead-acid batteries connected to it. It must be equipped with batteries with suitable capacity, dimensioned according to the system power ...
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
Compare
PS 4248 is a power supply unit suitable to get continuity power for EN 54-16 systems units like DXT 9000 and DXT 7000, and relevant complementary devices in case of mains power supply interruptions. It includes recharging and monitoring functions for the lead-acid batteries connected to it. It must be equipped with batteries with suitable capacity, dimensioned according to the system power ...
NOISE SENSOR
  • Up to 8 microphones can be connected on the rear panel
  • Specifically designed to work with for 100V speakers used as microphones. However, it can also be used with capsule microphones
  • Up 2 units can be connected to the same DXT 9000 amplifier
  • Presence led for each microphone
Compare
NS 9048 is a noise detector that automatically adjust the volume level depending on the environment noise. It is specifically addressed to all those applications with a significantly different people affluence during the day. It can be connected to any DXT 9000 power amplifiers and can act on every single system’s zones, measured with a variable number of microphones (up to a maximum of 8). ...
DXT 3000 MONITORED GPI BOARD
  • General purpose inputs monitoring
  • Detection and reporting of any open line or short circuit
  • General and single zone alarm activation
  • Reset function
Compare
...
LINE TRANSFORMER INTERFACE
  • The LT 7208 EN line transformer interface allows you to link/ group the 8 amplifiers to increase the power of the speaker lines two, three or four times
  • If the needed speaker line power is more than 80W, several outputs (in groups made of 2, 3 or 4) can be connected together (in parallel) in order to get locked groups for 160 W, 240 W or 320 W lines
  • Output line voltage setting (50-70-100 V) is made by changing the output tapping of each transformer
  • Includes also line specific 24V dc outputs for override relays (max. current: 1A / line)
Compare
...
DXT 3000 INTERLINK BOARD
  • Up to 8 units can be connected together
  • Fully redundant communication bus
  • Up to 4 BM 3804 (or BM 3804FM) can be connected to the MASTER unit, and each one can be extended with 8 BE 3806
  • Local paging for non-emergency purpose is also possible connecting to each unit a BM 3022 console
Compare
IE 3008 is an additional board for DXT 3000 that extends system’s capability and functionalities allowing the connection of a maximum of 8 units, in a MASTER / SLAVE configuration. It shall be installed in a dedicated slot inside the cabinet of each unit, that provide the 24V DC voltage necessary for its functioning. System units, each one with a fixed ID, communicates through a fully redundant ...
— 6 Items per Page