VOICE ALARM EN54

DOWNLOAD
CATALOGUE

DXT 9000 SYSTEM

DXT 9000 is the evolution to the RCF DXT Active Matrix solution range.
RCF has developed a brand news digital multi-platform system where PA-EVAC join PRO-INSTALL systems in a completely scalable and versatile range of configurations and solutions.
MASTER UNIT WITH ROUTER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
MASTER UNIT
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
4 X 125W AMPLIFIED MASTER UNIT
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC.
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
2 X 250W AMPLIFIED MASTER UNIT
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC.
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
4 X 125W POWER AMPLIFIER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
2 X 250W POWER AMPLIFIER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
1 X 500W POWER AMPLIFIER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
48 VCC POWER SUPPLY ACCORDING TO EN 54-4
  • Permanent and emergency power for installations
  • Performance and reliability for guaranteed power
  • Continuity of service of your installation through real time monitoring of system status
  • Control of the battery and its circuit: protection, management, self-diagnostic
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
48 VCC POWER SUPPLY ACCORDING TO EN 54-4
  • Permanent and emergency power for installations
  • Performance and reliability for guaranteed power
  • Continuity of service of your installation through real time monitoring of system status
  • Control of the battery and its circuit: protection, management, self-diagnostic
MULTI-ZONE EMERGENCY FIREMEN MICROPHONE
  • Complete self-diagnostic of the unit in compliance with EN 54-16/2008 standard
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
  • Programmable function keys for announcements or commands
  • Power supply voltage from the Flexicomm BUS or from 24V DC local input
MULTI-ZONE PAGING MICROPHONE
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
SELECTIVE CALL PAGING MICROPHONE
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
SELECTIVE CALL PAGING MICROPHONE
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
DATA REPEATER
  • RCF FLEXCOM BUS 4 Channels
  • Sampling frequency: 44.1 kHz
  • Operating temperature: -5° ÷ +50 °C (23 ÷ 122 °F)
  • Relative humidity: 20 ÷ 90% (non condensing)
NOISE SENSOR
  • Up to 8 microphones can be connected on the rear panel
  • Specifically designed to work with for 100V speakers used as microphones. However, it can also be used with capsule microphones
  • Up 2 units can be connected to the same DXT 9000 amplifier
  • Presence led for each microphone
INTEGRITY NETWORK CONSOLE
  • Up to 64 units connectable
  • 4 independent outputs lines
  • 2 monitored GPI (power supply and DXT 9000 fault)
  • 1 monitored GPO to communicate a console fault to DXT 9000
END OF LINE
  • Plastic case UL 94 V0
  • Ceramic terminal with termo-fuse for cables connection
  • To be used with RCF cables CV 210, CV 215, CV 225 (not included)
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.

DXT 7000 SYSTEM

DXT 7000 is a sound system conceived to completely control and manage background music and paging, even for emergency and evacuation purposes.
The system has been designed to fulfill all the requirements of EN 54-16 and EN 60849 standard, with full scalability
DIGITAL MATRIX DXT 7000
  • The system has been designed to fulfil all requirements of EN 54-16 and EN 60849 standard
  • Up to 32 units can be linked together in order to get an extended the systems
  • Up to 256 loudspeaker lines and many paging stations
  • The 8 digital internal amplifiers are highly reliable and excellent efficiency
LINE TRANSFORMER INTERFACE
  • The LT 7208 EN line transformer interface allows you to link/ group the 8 amplifiers to increase the power of the speaker lines two, three or four times
  • If the needed speaker line power is more than 80W, several outputs (in groups made of 2, 3 or 4) can be connected together (in parallel) in order to get locked groups for 160 W, 240 W or 320 W lines
  • Output line voltage setting (50-70-100 V) is made by changing the output tapping of each transformer
  • Includes also line specific 24V dc outputs for override relays (max. current: 1A / line)
POWER AMPLIFIER
  • Class D amplifier and double switching AC-DC power supply, transformer-less galvanic insulated speaker output
  • Pro audio performance
  • Selectable 70 – 100 V output per channel
  • Double input per channel
POWER AMPLIFIER
  • Class D amplifier and double switching AC-DC power supply, transformer-less galvanic insulated speaker output
  • Pro audio performance
  • Selectable 70 – 100 V output per channel
  • Double input per channel
POWER AMPLIFIER
  • Class D amplifier and double switching AC-DC power supply, transformer-less galvanic insulated speaker output
  • Pro audio performance
  • Selectable 70 – 100 V output per channel
  • Double input per channel
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
48 VCC POWER SUPPLY ACCORDING TO EN 54-4
  • Permanent and emergency power for installations
  • Performance and reliability for guaranteed power
  • Continuity of service of your installation through real time monitoring of system status
  • Control of the battery and its circuit: protection, management, self-diagnostic
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
48 VCC POWER SUPPLY ACCORDING TO EN 54-4
  • Permanent and emergency power for installations
  • Performance and reliability for guaranteed power
  • Continuity of service of your installation through real time monitoring of system status
  • Control of the battery and its circuit: protection, management, self-diagnostic
MICROPHONE CONSOLE WITH NUMERIC KEYPAD, LCD DISPLAY AND 24 CONFIGURABLE BUTTONS
  • Modern design
  • Monitored microphone
  • Audio input (3.5 mm TRS jack connector) for an external device
  • Up to 32 paging microphones in the entire system, up to 8 for each local bus
FIREMAN'S MICROPHONE PANEL WITH NUMERIC KEYPAD, LCD DISPLAY AND 8 CONFIGURABLE BUTTONS
  • Modern design
  • Monitored microphone
  • Audio input (3.5 mm TRS jack connector) for an external device
  • Up to 32 paging microphones in the entire system, up to 8 for each local bus
DESKTOP PAGING MICROPHONE
  • Modern design
  • Monitored microphone
  • Audio input (3.5 mm TRS jack connector) for an external device
  • Up to 32 paging microphones in the entire system, up to 8 for each local bus
DESKTOP PAGING MICROPHONE
  • Modern design
  • Monitored microphone
  • Audio input (3.5 mm TRS jack connector) for an external device
  • Up to 32 paging microphones in the entire system, up to 8 for each local bus
REMOTE PROGRAMME SELECTOR AND LEVEL CONTROL DEVICE
  • Zone group control
  • Program Selector
  • CAT5/6 compatible
SCHEDA INGRESSI LOGICI MONITORATI
  • Rileva eventuali cortocircuiti e linee aperte
  • Si possono connettere fino a 2 schede Si 7120 ad una singola unità MU 7100
  • LED rosso segnala il guasto sulle linee
DRY OUTPUT CONTACT BOARD FOR MU 7100EN
  • Converts open-collector to dry closing contacts
  • Resistors for alarm lines included
REMOTE LOCAL INPUT / CONTROL DEVICE
  • Connection and routing of a local program source
  • 3 progammable function keys
  • Wall mountable
CIRCUITO DI FINE LINEA
  • Monitors Speakers Lines Integrties
SPARE AMPLIFIER CHANGE OVER BOARD
  • Used to add a spare amplifier
  • There can be up to four AC 7212 connected to a single LT 7208 unit
  • 2 main 70-100V loudspeaker line inputs
  • Spare amplifier input and output
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.

DXT 3000 SYSTEM

DXT 3000 is a wall-mounting intelligent evacuation system dedicated to small and medium size applications, where an EN54-16 system is required.
MASTER UNIT WITH AMPLIFIERS
  • DSP-based Master Unit
  • Equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers
  • Spare power amplifier with automatic replacement
  • Internal power supply with battery charger and space for batteries
MASTER UNIT WITH AMPLIFIERS
  • DSP-based Master Unit
  • Equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers
  • Spare power amplifier with automatic replacement
  • Internal power supply with battery charger and space for batteries
MASTER UNIT WITH AMPLIFIERS
  • DSP-based Master Unit
  • Equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers
  • Spare power amplifier with automatic replacement
  • Internal power supply with battery charger and space for batteries
MASTER UNIT WITH AMPLIFIERS
  • DSP-based Master Unit
  • Equipped with 6 RCF Class D+ technology power amplifiers
  • Spare power amplifier with automatic replacement
  • Internal power supply with battery charger and space for batteries
MASTER UNIT WITH AMPLIFIERS
  • DSP-based Master Unit
  • Equipped with 2, 4 or 6 RCF Class D+ technology power amplifiers
  • Spare power amplifier with automatic replacement
  • Internal power supply with battery charger and space for batteries
MASTER UNIT WITH AMPLIFIERS
  • DSP-based Master Unit
  • Equipped with 2 RCF Class D+ technology power amplifiers
  • Spare power amplifier with automatic replacement
  • Internal power supply with battery charger and space for batteries
MULTI-ZONE EMERGENCY FIREMEN MICROPHONE
  • Complete self-diagnostic of the unit in compliance with EN 54-16/2008 standard
  • Power supply voltage from the BUS (first microphone only) or from 24V DC local input
  • Alert and evacuation indications.
  • Pre-recorded message activation.
DESK-TOP PAGING MICROPHONE
  • Casing in die-cast metal
  • Preamplified cardioid hi-quality microphone, with flexible 445 mm long
  • Comprehensive self-diagnostics (EN 54-16)
  • Connection cable included (5 m, with RJ 45)
ADDITIONAL KEYBOARD FOR BM 3804
  • Casing in die-cast metal
DXT 3000 MONITORED GPI BOARD
  • General purpose inputs monitoring
  • Detection and reporting of any open line or short circuit
  • General and single zone alarm activation
  • Reset function
DXT 3000 INTERLINK BOARD
  • Up to 8 units can be connected together
  • Fully redundant communication bus
  • Up to 4 BM 3804 (or BM 3804FM) can be connected to the MASTER unit, and each one can be extended with 8 BE 3806
  • Local paging for non-emergency purpose is also possible connecting to each unit a BM 3022 console
END OF LINE
  • Plastic case UL 94 V0
  • Ceramic terminal with termo-fuse for cables connection
  • To be used with RCF cables CV 210, CV 215, CV 225 (not included)
BATTERIES
  • Batteries for DXT 3000 System
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.

SPEAKERS

Dangerous situations may occur in any place where people live and work. The effective and efficient evacuation of sensitive areas must be implemented in conditions of maximum safety for all occupants, avoiding panic as much as possible.
The EN54 series fulfills all the requirements of the EN 54 - Fire detection and fire alarm systems standard.
2 WAYS CEILING SPEAKER FIRE DOME
  • Speaker for transmitting alarm voice messages with high intelligibility and background music
  • Power (selectable) at 100V: 20 W – 10 W – 5 W
  • 8" diameter wide band loudspeaker
  • Steel protection Fire Dome, terminal strip in ceramic material for connecting flameproof input and output cables, thermal fuse, suitable internal wiring
CEILING SPEAKER FIRE DOME
  • Speaker for transmitting alarm voice messages with high intelligibility and background music
  • Music power/RMS: 24/6W
  • 6" diameter dual cone wide band loudspeaker
  • Low impedance (8Ω) or 100V
CEILING SPEAKER FIRE DOME
  • Speaker for transmitting alarm voice messages with high intelligibility and background music
  • Power (selectable) at 100V: 6 W – 3 W – 1.5 W (power values are halved at 70 V)
  • 6" diameter dual cone wide band loudspeaker
  • Steel protection Fire Dome, terminal strip in ceramic material for connecting flameproof input and output cables, thermal fuse, suitable internal wiring
CEILING SPEAKER FIRE DOME
  • Speaker for transmitting alarm voice messages with high intelligibility and background music.
  • Power (selectable) at 100V: 6 W – 3 W – 1.5 W – 0,75W
  • 5" diameter wide band loudspeaker
  • Steel protection Fire Dome, terminal strip in ceramic material for connecting flameproof input and output cables, thermal fuse, suitable internal wiring
CEILING SPEAKER WITH PLASTIC FIRE DOME
  • Speaker for transmitting alarm voice messages with high intelligibility and background music
  • Power (selectable) at 100V: 6 W – 3 W – 1.5 W
  • 5" diameter wide band loudspeaker
  • Plastic protection Fire Dome, terminal strip in ceramic material for connecting flameproof input and output cables, thermal fuse, suitable internal wiring
UNIDIRECTIONAL SOUND PROJECTOR
  • 5'' full range speaker for alarm voice messages broadcasting and high quality background music
  • ABS cabinet with steel mesh grille
  • It can be installed both indoors and outdoors (IP 65 protection grade)
  • Equipped with transformer for 100 V (/ 70 V) constant voltage lines
UNIDIRECTIONAL SOUND PROJECTOR
  • 5’’ full range speaker for alarm voice messages broadcasting and high quality background music
  • ABS cabinet with aluminum grille.
  • It can be installed both indoors and outdoors (IP 55 protection grade).
  • Equipped with transformer for 100 V (/ 70 V) constant voltage lines.
ALUMINIUM SOUND PROJECTOR
  • Unidirectional sound projector characterized by high acoustic performance
  • Complying with EN 54-24 standard thanks to ceramic termination block, thermal fuse and internal fi re-resistant cable
  • IP 66 protection, suitable for outdoor use
  • It's ideal for train stations, underground stations, car parks, factories, warehouses, and PA systems in general
BIDIRECTIONAL SOUND PROJECTOR
  • 5'' full range speaker for alarm voice messages broadcasting and high quality background music
  • ABS cabinet with steel mesh grille
  • It can be installed both indoors and outdoors (IP 65 protection grade)
  • Equipped with transformer for 100 V (/ 70 V) constant voltage lines
ALUMINIUM BIDIRECTIONAL SOUND PROJECTOR
  • Bidirectional sound projector with double loudspeaker, characterized by high acoustic performance, excellent design and compact dimensions
  • Complyin with EN54-24 stanard thanks to ceramic termination block, thermal fuse and internal fire-resistant cable
  • IP 66 protection, suitable for outdoor use
  • It's idea for train stations, underground stations, car parks, factories, warehouses, and PA systems in general
WALL/CEILING UNIVERSAL STEEL SPEAKER
  • Speaker designed for transmitting alarm messages with high intelligibility, and background music
  • Musical power/RMS: 12/6W
  • Wide-band dual cone loudspeaker, diameter 5"
  • Extra-thick steel housing, terminal strip for connections made of ceramic material for fl ameproof input and output cables, thermal fuse, suitable internal wiring
UNIVERSAL WALL MOUNT PLASTIC SPEAKER
  • 5.5’’ full range speaker for alarm voice messages broadcasting and high quality background music
  • ABS enclosure with powder coated grille.
  • Equipped with transformer for 100 V (/ 70 V) constant voltage lines
  • Internal power setting
WALL/CEILING UNIVERSAL STEEL SPEAKER
  • Speaker designed for transmitting alarm messages with high intelligibility, and background music
  • Musical power/RMS: 12/6W
  • Wide-band dual cone loudspeaker, diameter 5"
  • Extra-thick steel housing, terminal strip for connections made of ceramic material for fl ameproof input and output cables, thermal fuse, suitable internal wiring
2 WAYS BASS REFLEX MONITOR SPEAKERS
  • Speaker for transmitting alarm voice messages with high intelligibility and background music.
  • Power (selectable) at 100V: 30W - 15W - 7.5W - 3.75W
  • 5'' woofer and 1'' tweeter
  • Available both in black and white
COLUMN SPEAKER TWO-WAY
  • Ideal for speech reproduction with high intelligibility in acoustically diffi cult environments, both indoors and outdoors, also suitable for music
  • Music power/RMS: 40/20W
  • Four 3" mid-woofer speakers and one central 20mm tweeter
  • Weather-resistant construction IP 66 for use also outdoors, sturdy hinged support in resin, stainless steel fasteners
COLUMN SPEAKER TWO-WAY
  • Ideal for speech reproduction with high intelligibility in acoustically difficult environments, both indoors and outdoors, also suitable for music
  • RMS power: 40 W
  • Eight 3.5" mid-woofer speakers and one central 0.79'' voice coil tweeter
  • Weather-resistant construction IP 66 for use also outdoors, sturdy hinged support in resin, stainless steel fasteners
SUSPENDED SOUND PROJECTOR
  • 5'' coaxial speaker for alarm voice messages broadcasting and high quality background music.
  • ABS cabinet with steel mesh grille
  • It can be installed both indoors and outdoors (IP 65 protection grade)
  • Equipped with transformer for 100 V (/ 70 V) constant voltage lines
LONG-THROW MULTI CELL HORN SPEAKER
  • Long-throw horn speaker
  • Body in RAL 9003 white fiberglass
  • Mounting bracket
  • Mounting bracket Protection grade IP55
PLASTIC HORN SPEAKER
  • Horn speaker with 30W driver
  • Transformer for 100 V (/ 70 V) constant voltage connection
  • Suitable for indoor and outdoor use (thanks to IP 66 protection)
  • UV stabilized self-extinguishing ABS body
PLASTIC HORN SPEAKER
  • Compact speaker with 30 W driver in compliance with EN 54-24
  • Rear cover in UV stabilised self-extinguishing ABS
  • Suitable for indoor and outdoor use (thanks to IP 66 protection)
  • Transformer for 100 V (/ 70 V) constant voltage connection
.