VOICE ALARM EN54

DOWNLOAD
CATALOGUE

DXT 9000 SYSTEM

DXT 9000 is the evolution to the RCF DXT Active Matrix solution range.
RCF has developed a brand news digital multi-platform system where PA-EVAC join PRO-INSTALL systems in a completely scalable and versatile range of configurations and solutions.
MASTER UNIT WITH ROUTER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
MASTER UNIT
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
4 X 125W AMPLIFIED MASTER UNIT
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC.
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
2 X 250W AMPLIFIED MASTER UNIT
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC.
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
4 X 125W POWER AMPLIFIER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
2 X 250W POWER AMPLIFIER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
1 X 500W POWER AMPLIFIER
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Electronic apparatus safety requirements according to IEC EN 60065:2002
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 6 main outputs to system's units
  • 4 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
48 VCC POWER SUPPLY CERTIFIED EN 54-4
  • 4 main outputs to system's units
  • 2 auxiliary outputs
  • Permanent and emergency power for installations
  • Continuity of service of your installation through real time monitoring of system status
MULTI-ZONE EMERGENCY FIREMEN MICROPHONE
  • Complete self-diagnostic of the unit in compliance with EN 54-16/2008 standard
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
  • Programmable function keys for announcements or commands
  • Power supply voltage from the Flexicomm BUS or from 24V DC local input
MULTI-ZONE PAGING MICROPHONE
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
SELECTIVE CALL PAGING MICROPHONE
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
SELECTIVE CALL PAGING MICROPHONE
  • EN 54-16/2008
  • CE: it complies with European Community 2006/95/CE LVD and 2004/108/CE EMC
  • Electromagnetic immunity according to IEC EN 55013+A1+A2, IEC EN 55020+A2+EC, EN 61000-3-2, EN 61000-3-3+A1
  • Up to 8 microphone consoles can operate on each dedicated connection line. Their configuration in terms of access can be set by the PC system interface
DATA REPEATER
  • RCF FLEXCOM BUS 4 Channels
  • Sampling frequency: 44.1 kHz
  • Operating temperature: -5° ÷ +50 °C (23 ÷ 122 °F)
  • Relative humidity: 20 ÷ 90% (non condensing)
NOISE SENSOR
  • Up to 8 microphones can be connected on the rear panel
  • Specifically designed to work with for 100V speakers used as microphones. However, it can also be used with capsule microphones
  • Up 2 units can be connected to the same DXT 9000 amplifier
  • Presence led for each microphone
INTEGRITY NETWORK CONSOLE
  • Up to 64 units connectable
  • 4 independent outputs lines
  • 2 monitored GPI (power supply and DXT 9000 fault)
  • 1 monitored GPO to communicate a console fault to DXT 9000
END OF LINE
  • Plastic case UL 94 V0
  • Ceramic terminal with termo-fuse for cables connection
  • To be used with RCF cables CV 210, CV 215, CV 225 (not included)
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.
FIRE RESISTANT DATA CABLE
  • Fire resistant cables for data with conductor thickness of 0.8 mm shielded.
SPEAKER CABLE 100V SECTION 2 X 2.5 MMQ
  • FIRE RESISTANT
SPEAKER CABLE 100V SECTION 2 X 1.5MMQ
  • FIRE RESISTANT
SPEAKER CABLE 100V SECTION 2 X 1 MMQ
  • FIRE RESISTANT
DESKTOP PAGING MICROPHONE